Carbon Monoxide on Construction Sites: Understanding the Hidden Danger
During colder weather, a temporary heater might be brought into an unfinished building so work can continue. Elsewhere on site, a generator may be running outside, close to an open doorway. Neither situation necessarily looks unusual, but the position of fuel-burning equipment and where its exhaust fumes can travel deserve attention.
Carbon monoxide cannot be seen or smelt, making it particularly difficult to recognise when something is wrong. Someone exposed to the gas might develop a headache or begin feeling dizzy without realising what’s causing it. The risk isn’t limited to heaters, either. Petrol-powered tools and vehicle exhausts can also create problems in areas where fumes collect.
Knowing how exposure can happen, and what precautions are needed, can help construction teams recognise potentially dangerous working conditions before someone becomes ill.
What Is Carbon Monoxide and Why Is It Dangerous?
A generator could start without any problems, sound perfectly normal and still be producing carbon monoxide (CO). The gas forms when fuels don’t burn completely, which can happen with petrol, diesel and gas appliances. There’s no unusual smell or visible sign to alert workers to its presence. Even equipment that appears to be operating normally can release it.
Once breathed in, carbon monoxide passes into the blood and binds to haemoglobin, leaving less available to carry oxygen around the body. The brain and heart are particularly sensitive to this lack of oxygen. With heavy exposure, someone can become seriously ill in a matter of minutes. They may lose consciousness, and severe poisoning can cause permanent injury or prove fatal.
Consider a room that’s been partially closed off with temporary sheeting to keep out the cold. If fuel-burning equipment is used there, exhaust gases may have nowhere to escape. A similar problem can arise in an excavation if petrol-powered equipment is used below ground level, where the surrounding ground can restrict how fumes disperse.
Where Can Carbon Monoxide Exposure Occur on Construction Sites?
During refurbishment work, a petrol-powered cut-off saw may be needed to cut through an existing floor or wall. Using it inside the building can quickly become dangerous, even if the work only takes a few minutes. The same concern applies to generators and engine-driven compressors. A generator left running outside could still cause problems if its exhaust fumes are drawn back through an open window or doorway.
Some construction tools, such as pneumatic drills, run on compressed air rather than fuel. The drill itself doesn’t produce exhaust fumes, although the petrol- or diesel-powered compressor supplying the air may do so.
During colder months, portable heaters are often used to warm temporary working areas. Gas-powered heaters can become dangerous if they’re faulty or used without adequate ventilation. This also applies to fuel-burning appliances in site welfare facilities, especially where ventilation openings have been covered to keep out draughts.
Exhaust fumes from vehicles and heavy machinery deserve attention too. A delivery lorry might be left idling while materials are unloaded into a partially covered area, or an excavator could be operating near an open basement. Even though the engines are running outside, fumes may still find their way into areas where people are working.
Welding and oxy-acetylene cutting can produce carbon monoxide alongside other hazardous fumes and gases. Inside a tank or enclosed structure, there may be very little airflow to carry these away. A welder could be working in an area where gases are collecting without being able to see or smell them. Work in these conditions needs careful assessment and suitable controls before anyone enters the space.
Recognising the Symptoms of Carbon Monoxide Poisoning
A headache during a long shift might be put down to tiredness or not drinking enough water. If someone starts feeling dizzy or nauseous as well, they may assume they’re coming down with an illness. These are also common symptoms of carbon monoxide poisoning, which can make it difficult to recognise what’s actually happening.
A worker might feel unusually tired halfway through a task they’d normally manage without any trouble. They may also notice that their legs feel weak or find it harder to follow instructions during a conversation. One warning sign is feeling worse while working in a particular area, then noticing that the symptoms improve after going outside for fresh air.
More serious exposure can cause confusion, chest or muscle pain and difficulty breathing. Someone may complain that their face feels unusually hot or appears flushed. Their eyesight can also be affected, with severe poisoning sometimes causing a complete loss of vision.
If carbon monoxide is suspected, everyone should leave the affected area and move into fresh air. The site supervisor should be informed so that nobody else enters. Anyone experiencing possible symptoms should seek medical advice promptly through NHS 111. Chest pain, breathing difficulties, sudden confusion, marked weakness or loss of consciousness require emergency assistance by calling 999. The area should remain out of use until the source has been investigated and the space made safe.
How Can Construction Sites Prevent Carbon Monoxide Exposure?
Before work begins, site managers should consider whether any of the equipment being used could produce carbon monoxide. A petrol-powered saw might be suitable for cutting materials outside, but it shouldn’t automatically be brought indoors to finish another job. Electric or battery-powered alternatives can remove the need for an engine in the working area.
Ventilation also needs careful consideration. A generator positioned outside should be far enough from doors and windows that exhaust fumes cannot drift back into the building. Petrol-powered equipment must not be used in confined spaces, and opening a window doesn’t necessarily make it safe to operate inside other enclosed areas. Where indoor use is being considered, the HSE advises seeking specialist help to assess the ventilation requirements.
Carbon monoxide detectors can provide an additional warning where a risk assessment identifies the need. Depending on the work, this might involve workers carrying personal gas monitors or having fixed detectors in particular areas. They need to be suitable for the conditions and maintained correctly. A detector shouldn’t be relied upon as a replacement for controlling the source of the gas.
The installation of gas appliances deserves attention too, particularly during refurbishment work. An existing boiler flue could be damaged or obstructed while other building work is taking place. Gas installation and repair work should be carried out by competent people, with Gas Safe registration required for certain types of work and premises.
Equipment also needs checking once it’s in use. A gas heater that worked properly last winter may have developed a fault while in storage. Blocked burners or damaged components can affect how fuel burns and increase the amount of carbon monoxide produced. Following the manufacturer’s maintenance instructions and investigating faults before equipment is used again can prevent these problems from being overlooked.
What Does UK Health and Safety Law Require?
A risk assessment carried out at the start of a project might not account for a new generator or fuel-burning heater brought onto site several weeks later. If the equipment or working conditions change, the risks need reviewing before work continues. Carbon monoxide exposure is covered by the Control of Substances Hazardous to Health (COSHH) Regulations 2002, which require employers to assess the risks and prevent exposure where reasonably practicable, or otherwise control it adequately.
The findings need to be reflected in how work is carried out. A safe system of work might specify which equipment can be used in a particular area, who is responsible for checking the conditions and what should happen if carbon monoxide is suspected. Where the work falls under the Confined Spaces Regulations 1997, there are further requirements, including suitable emergency arrangements before anyone enters.
Workers also need to understand the risks associated with their tasks. Someone arriving on site to carry out a short-cutting job may not know about restrictions on fuel-powered equipment unless they’ve been told. Site inductions and task briefings should cover the relevant precautions, with further instruction provided when working arrangements change.
A site supervisor may have plenty of experience managing construction work without having the specialist knowledge needed to assess complicated ventilation arrangements. There are situations where advice from someone with the right technical experience will be needed. Employers must appoint competent people to assist with their health and safety responsibilities, while certain jobs, including gas appliance installation and repair, have their own competence requirements.
Businesses employing five or more people must also have a written health and safety policy. This should explain who is responsible for managing risks and how safety arrangements are put into practice. On a construction project, those arrangements need to remain relevant as different contractors arrive and work moves into new areas of the site.
Managing Carbon Monoxide Risks on Construction Sites
A contractor might have used a petrol-powered cutter outside earlier in the week. If the next job involves cutting inside a building, the original working arrangements are no longer suitable. The equipment hasn’t changed, but the place it’s being used has, and that can make a considerable difference to the risk of carbon monoxide exposure.
Site managers need to be aware of changes like these before work begins. An earlier risk assessment may need reviewing if new equipment is introduced or an area becomes enclosed as the project develops. With carbon monoxide, there may be nothing obvious to alert workers that dangerous fumes are building up.
Hurst Setter provides risk assessment services and on-site health and safety advice for construction businesses. If you need assistance with risk assessments or managing health and safety on a construction project, contact Hurst Setter to discuss how the team can support you.
Speak with our Safety Experts